KAJIAN TENTANG PERLAKUAN JARAK ANTAR ELEKTRODA TEMBAGA TERHADAP KINERJA SENSOR KONDUKTIVITAS LISTRIK TANAH TIPE KAPASITIF

Authors

  • Gede Andri Program Studi Teknik Pertanian, Fakultas Teknologi Pertanian, Universitas Udayana
  • I Made Anom. S. Wijaya Program Studi Teknik Pertanian, Fakultas Teknologi Pertanian, Universitas Udayana
  • I Gede Putu Budi Sanjaya Program Studi Teknik Pertanian, Fakultas Teknologi Pertanian, Universitas Udayana

DOI:

https://doi.org/10.24843/j.beta.2015.v03.i01.p01

Keywords:

Electric conductivity (EC), capacitive sensor, parallel chip sensor electrode, soil frequency, performance test

Abstract

The measurement of EC can be conducted in two ways, namely electromagnetic induction and direct contact. This study using capacitive direct contact. The aims of this study were to determine the relationship between distance, shape and electrode materials to the measurements performance, and to determine to treatment that has the best performance. The study was started by designing the electrodes then continued by functional test and performance test. The treatments used was electrodes distances of 3, 6, 9, 12 & 15 mm. The electrode probe was inserting into the soil with the depth of 20 cm to get the frequency and at the same time soil sample was collected for analyzed in the laboratory to get the EC values. Based on those data the relationship of between soil frequency and EC were then analyzed. The results indicated that the best performance electrode with distance 3 mm. The equation of soil frequency and EC was EC = 0.186875 Fsoil - 10.5695 with R2 = 0.861, RMSE = 0.04, stability = 0.04 and respond time = 37.35 second.

References

Asdak, C, 2010, Hidrologi dan Pengelolaan Daerah Aliran Sungai, Gadjah Mada University Press, Yogyakarta.

Cifriadi Adi, Barnas Holil, Munawar A. Riyadi (2005) Karakteristik Film Polisulfon Sebagai Bahan Dielektrik Sensor Kelembaban Jenis Kapasitif. Balai Penelitian Teknologi Karet Bogor.

Doran JW & Parkin. (1994). Definning and assessing soil quality, IN J.W. Doran D.C. Coleman D.F. Bezdick and B.A Hakim,A.,R. 2011. Perancangan Sistem Informasi Pengukuran Konduktivitas Hidraulik Tidak Jenuh Tanah dengan Sensor Tensiometer dan Higrometer Digital. SKRIPSI-S1 Jurusan Teknik Elektro Fakultas Teknik Universitas Jember.

Rhoades, J.D., D.L. Corwin, and S.M. Lesch. 1999b. Geospatial measurements of soil electrical conductivity to assess soil salinity and diffuse salt loading from irrigation. p. 197–215. In D.L. Corwin, K.Loague, and T.R. Ellsworth (ed.) Assessment of non-point sourceApplication of Soil Electrical Conductivity to Precision Agriculture:Theory, Principles, and Guidelines

D. L. Corwin* and S. M. Lesch Sudduth, K.A., N.R. Kitchen and S.T. Drummond. 1998. Soil conductivity sensing on claypan soils: Comparison of electromagnetic induction and direct methods. Proc. of the 4th

Suprapto,NM. 2006. Uji Konduktivitas Listrik Terhadap Kadar Air Tanah Dermaga Bogor dan Metode Wenner dan Sifat Fisik Tanahnya. Dapartemen Fisika Fakultas Matematika dan Ilmu Pengetahuan IPB. Tipler, P.1991.Fisika Untuk Sains dan Teknik, Edisi ke-3 jilid 2.Erlangga.Jakarta.

Published

2026-02-03

How to Cite

Andri, G., Wijaya, I. M. A. S., & Sanjaya, I. G. P. B. (2026). KAJIAN TENTANG PERLAKUAN JARAK ANTAR ELEKTRODA TEMBAGA TERHADAP KINERJA SENSOR KONDUKTIVITAS LISTRIK TANAH TIPE KAPASITIF. Jurnal BETA (Biosistem Dan Teknik Pertanian), 3(1), 1–12. https://doi.org/10.24843/j.beta.2015.v03.i01.p01

Issue

Section

Articles