URINE ANALYSIS OF ETAWA BREED GOATS IN SUKAWATI DISTRICT, GIANYAR REGENCY BALI

Authors

  • Gusti Putu Arni Safitri Mahasiswa Program Sarjana Kedokteran Hewan, Fakultas Kedokteran Hewan, Universitas Udayana, Jl. PB. Sudirman, Denpasar, Bali, Indonesia, 80234
  • Anak Agung Sagung Kendran Laboratorium Patologi Klinik Veteriner, Fakultan Kedokteran Hewan, Universitas Udayana, JL. PB. Sudirman Denpasar, Bali, Indonesia, 80234
  • Luh Gde Sri Surya Heryani Laboratorium Anatomi dan Embriologi Veteriner, Fakultas Kedokteran Hewan, Universitas Udayana, Jl. PB. Sudirman Denpasar, Bali, Indonesia
  • Ida Bagus Komang Ardana Laboratorium Patologi Klinik Veteriner, Fakultan Kedokteran Hewan, Universitas Udayana, JL. PB. Sudirman Denpasar, Bali, Indonesia, 80234
  • I Nyoman Suarsana Laboratorium Biokimia Veteriner, Fakultan Kedokteran Hewan, Universitas Udayana, JL. PB. Sudirman Denpasar, Bali, Indonesia, 80234
  • Sri Kayati Widyastuti Laboratorium Ilmu Penyakit Dalam Veteriner, Fakultas Kedokteran Hewan Universitas Udayana, Jl. Raya Sesetan Gg. Markisa No. 6, Denpasar Selatan, Bali, Indonesia
  • Romy Muhammad Dary Mufa Laboratorium Kesehatan Masyarakat Veteriner, Fakultas Kedokteran Hewan, Universitas Udayana, Jl. PB. Sudirman, Denpasar, Bali, Indonesia 80234

DOI:

https://doi.org/10.24843/bulvet.2024.v16.i03.p07

Keywords:

analysis, goats, urine

Abstract

Etawa crossbreed goats (Capra aegagrus hircus) are livestock that are starting to be developed among breeders. In goat farming there are health problems that arise both clinically and subclinically, including disorders of the urinary tract. This study aims to determine the clinical condition of Etawa crossbreed goats (PE) in Sukawati District, Gianyar Regency by using urine examination. This study used 30 urine samples from Etawa crossbreed goats at the Raka Etawa Farm. A total of 10-30 ml of urine is taken using the mid-stream method and collected in a urine container which is then tested using a dipstick pad. This research is an observational study with a cross sectional study design using a purposive sampling method. Based on the results of the examination, data was obtained in the form of specific gravity (BJ) with a range of 1,005-1,010 and an average of 1.00567; pH in the range 8-9 and an average of 8.867; a total of 18 samples were found to contain proteins in the range 15-30 and an average of 15.83; and negative results were found in the parameters glucose, negative bilirubin, ketones, erythrocytes, urobilinogen, nitrites and leukocytes. These results indicate that the clinical condition of Etawa crossbreed goats (PE) is healthy (not sick) through urine examination in the form of physical examination and dipstick. It is necessary to carry out additional examinations in the form of examination of urine sidemen and bacterial culture, as well as measuring the specific gravity (BJ) using a refractometer to obtain a more accurate value.

Downloads

Published

2024-06-04